SEW MOVITOOLS
versiondog supports the management of MOVITOOLS® MotionStudio projects and enables the cyclical monitoring of units that were projected in this development environment.
From version |
MOVITOOLS® MotionStudio |
||||||
---|---|---|---|---|---|---|---|
5.6.0: SP1 |
5.72 | 6.0.0.1 | 6.10 | 6.20 | 6.30 | 6.40 | |
versiondog 3.3.3 | ✓* | ✓* | ✓ | ||||
versiondog 8.1.5 | ✓* | ✓* | ✓ | ✓ | ✓** | ✓** | ✓** |
* Upload only
** Upload requires running the service(s) in application mode.
Example for the server:
"C:\Program Files (x86)\vdogServer\VDogMasterService.exe" /at:s /rd:D:\vdServerArchive /app /visible Example for the agents:
"C:\Program Files (x86)\vdogAgents\VDogCompareAgent.exe" /at:s /rd:D:\vdAgentArchive /app /visible
"C:\Program Files (x86)\vdogAgents\VDogUploadAgent.exe" /at:s /rd:D:\vdAgentArchive /app /visible
Other requirements
A licensed version of MOVITOOLS® MotionStudio must be installed on the versiondog server or the computer from which the upload is performed (server or agent).
Devices supported by SEW-EURODRIVE:
MOVIDRIVE (B)
MOVITRAC (B)
MOVIAXIS
MOVIMOT (D)
MOVIFIT (Technology, Classic)
MOVIGEAR (DSC, DAC, DBC, SNI)
DRC (DSC, DAC, DBC, SNI)
MOVIPRO (SK, SDC, ADC)
MOVI-PLC (basic, advanced)
CCU (advanced, power)
Key features and functions
Detail comparator for configuration and firmware (version detailed comparison) |
Automatic detection of program changes (version and backup detailed comparison) |
SmartCompare for MOVITOOLS® MotionStudio projects (version detailed comparison) |
Clear presentation of complete change history |
Component type for MOVITOOLS® MotionStudio projects |
Integrated MOVITOOLS® MotionStudio project tree |
Open the editor directly from versiondog |
Upload configuration for MOVITOOLS® MotionStudio |
Notes about the comparison
- Device data is compared with the VarData-Interpreter application from MOVITOOLS® MotionStudio.
- Devices that are solely connected through Networks will not be taken into consideration when comparing the parameters.
- In addition to the parameters that are excluded by the VarData-Interpreter, versiondog also excludes the following parameters:
8455.0: PA1 setpoint | 9081.0: Debug address 5 |
8456.0: PA2 setpoint | 9082.0: Debug address 6 |
8457.0: PA3 setpoint | 9083.0: Debug address 7 |
8458.0: PE1 actual value | 9084.0: Debug address 8 |
8459.0: PE2 actual value | 9085.0: Debug Index 1 and 2 |
8460.0: PE3 actual value | 9086.0: Debug Index 3 and 4 |
8705.0: Sampling time | 9087.0: Debug Index 5 and 6 |
8706.0: Scope follow-up cycles | 9088.0: Debug Index 7 and 8 |
8707.0: Scope Trigger Source | 9089.0: Trigger behaviour |
8708.0: Scope rising edge | 9090.0: Trigger selection |
8717.0: Scope Debug Address 1 | 9091.0: Trigger source |
8718.0: Scope Debug Address 2 | 9092.0: Trigger mode |
8719.0: Scope Debug Address 3 | 9093.0: Analogue trigger level |
8720.0: Scope Debug Address 4 | 9094.0: Analogue trigger hysteresis |
9095.0: Analogue trigger mask |
In this tutorial:
Last updated: 1 September 2023